Noise-control cabins
Where a noise source can be enclosed, a well-designed soundproof enclosure reduces noise at the machine without unnecessarily restricting its operation. We tailor each noise-control cabin to the source it contains.

Custom soundproofing cabins

For small and medium-sized installations, we use a modular acoustic enclosure with customisable dimensions, weight and features.
For very large projects, we offer solutions based on the FAIST cabin system — the same engineering approach, at a scale capable of enclosing complete plant and sections of production halls.
Modular noise-proof cabins

The frame uses aluminium profiles and is made to your required dimensions — the cabin is designed around the machine, not the other way round.
Panels and their fastenings. Selected according to the access required in operation:
- screw-fixed panels — for areas that remain closed
- quick-release fasteners operated with a separate square key — for quick access while preventing accidental opening
- as a door, with hinges and quick-release latches — where regular access is required during operation
Three weight options. The right choice depends not on the noise level but on the frequency content of the machine noise: low-frequency components require mass, while high-frequency components are considerably easier to attenuate. If you have a spectrum for your machine, send it with your enquiry — otherwise we can measure it.
Custom penetrations for pipes, hoses and cables are incorporated into the panels instead of being cut afterwards. An opening shown on the drawing is a planned sound path; one made on site is a leakage path.
Ventilation

Noise-proofing cabins need effective ventilation to prevent machines from overheating. Air is routed through an acoustically attenuated airflow path — passively where natural draught is sufficient, and with a centrifugal fan where the machine requires more cooling.
We calculate the heat load before building the cabin and select the ventilation system accordingly.
Noise control for coolers

Dry coolers such as those on the roofs of data centres run day and night and need a great deal of air — a closed cabin is not an option for them. For these we offer the FAIST enclosure: above the fans, an attenuated hood carries the warm exhaust air away, along the long sides the intake air flows in through splitter silencers, and doors keep the coolers accessible for maintenance. We calculate how much attenuation is needed and how much pressure drop the fans can tolerate for each installation.

From measurement to acceptance
Each industrial soundproofing cabin is a small engineering project. We handle it from start to finish:
- On-site measurement: the machine's sound radiation, dominant sources and frequency content — the basis for panel selection and design.
- Site survey and dimensions: the available space, where the machine is operated, loaded and maintained, and where services must pass through.
- Concept and calculation: expected insertion loss, heat balance and airflow rates — so the cabin reduces noise without restricting the machine.
- On-site installation: we assemble the cabin ourselves. The difference between calculated and achieved insulation almost always lies in joints, penetrations and connections — so we also complete the finishing work, for performance and appearance.
- Verification measurement: on request, we measure again after installation. The report then quantifies the noise reduction achieved by the cabin.
Engineered for your application
These systems are custom-designed for the geometry, noise spectrum and operating conditions of each application. Tell us about the problem, and we will explain whether and how we can address it.