Acoustic measurements & analysis

We measure and analyse airborne sound, structure-borne sound and vibration using standardised methods and METAS-calibrated instruments, and archive the raw data. We continually expand our range of equipment. If the measurement you need is not listed here, call us.

Acoustician measuring sound from a ventilation system on a roof.

Troubleshooting, root-cause analysis and source localisation

Acoustic camera in front of an open panel saw; the superimposed false-colour image locates the sound at the saw blade.

Something hums, drones or vibrates, and nobody has been able to solve the problem. We encounter this often. Finding the cause is our everyday work — and it determines whether a proposed solution will work or simply cost money. Before recommending changes, we establish the source and transmission path.

Where conditions permit, we use a specialised localisation method — simultaneously recording multiple microphone and structure-borne-sound signals. This separates the source from the path quickly instead of leaving room for speculation later. Depending on the frequency range and accessibility, we also use:

For an initial assessment, we also analyse original files that you recorded yourself with a smartphone, pocket recorder or measurement microphone. Send the unchanged file together with the location, date, time and a brief description of what you heard. Such recordings can reveal rhythm, tonality and possible source categories. They do not, however, provide formal, calibrated evidence of sound level. Files compressed by messaging apps are less suitable.

Noise measurements / sound measurements

Acoustician measuring sound pressure level between two industrial presses; the measurement microphone is mounted on a tripod.

Accurate sound pressure level measurements help answer two essential questions: is action required by law, and what do we need to know about the noise to reduce it effectively?

Vehicles:

Building construction and building services:

Environmental noise:

Industry:

Acoustic data, hum and vibration analysis

Spectrogram of a low-frequency disturbance — tonal peak with harmonics.

As neighbourhoods become more densely built and heat pumps, ventilation and air-conditioning systems become more common, more people experience unwanted noise in their living rooms and bedrooms. Low-frequency humming and throbbing are typical. Even at low to moderate levels, these sounds can be very disturbing.

Root-cause investigation is particularly difficult at low frequencies: sound sources may be within the building itself (structure-borne sound) or outdoors in the surrounding area. The character of the sound often provides the decisive clue.

The investigation becomes harder when such sounds are not continuously present. A hum linked to a control system or operating cycle may fall silent during the on-site measurement itself — in that case a recording must run long enough to "capture" it.

Structure-borne sound, vibration & NVH

Accelerometer on the base of technical equipment during a structure-borne sound measurement.

In structure-borne sound, deformation waves propagate through solid structures where wave-propagation laws apply, meaning the structural dimensions are typically substantially greater than one wavelength — transmission paths and coupling points are decisive.

Here, vibration means oscillatory motion at frequencies where the structure is substantially smaller than the wavelength. The simplified model is therefore the motion of a rigid mass — translation and rotation, and the isolation provided by its mountings, are decisive.

We measure structure-borne sound and vibration using piezoelectric accelerometers. Where noise and vibration are assessed together — referred to as NVH, for noise, vibration, harshness, in vehicle and machine development — we record multiple microphone and accelerometer channels simultaneously and evaluate them for the question at hand:

Sound power EN ISO 3744 / EN ISO 3746

Sound power measurement on a large mobile fan outdoors, with a measurement microphone on a tripod.

We determine sound power for various sources:

We use the enveloping-surface measurement method in accordance with EN ISO 3744 or EN ISO 3746, in accuracy grade 2 or 3.

Sound intensity EN ISO 9614

3D sound-intensity measurement on a transformer — custom eight-channel probe, measurement grid and intensity vectors at 100 Hz.

Sound pressure indicates how loud it is at a point. Sound intensity additionally shows the direction in which energy flows — helping us target noise control where it will be effective. It is also the basis of another standardised method for determining sound power where an enveloping-surface method fails because of extraneous noise or reflections: measurement at discrete points (EN ISO 9614-1) or scanning the enveloping surface (EN ISO 9614-2). We use two custom-built probes for this purpose:

The practical advantage of the 3D probe appears where accurate conventional measurement is otherwise impossible: large outdoor equipment — transformers, generators, dry coolers and data-centre fans — is surrounded by reflective surfaces. A pressure-only measurement can no longer separate the direct component from the reflected one; direction-resolved intensity measurement can. This allows the radiation from an individual item of equipment to be quantified even between neighbouring buildings.

Sound insulation EN ISO 16283 / EN ISO 140

Sound insulation measurement shown as a two-part composite: substitute sound source in the heat-pump plant room and measurement microphone in the living space.

Modern building construction places high demands on acoustic separation by building elements, walls and the building envelope. Precise knowledge of sound insulation performance is essential for identifying weak points or assessing build quality.

Sound absorption EN ISO 354 and EN ISO 10534-2

CAD model of an impedance tube with loudspeaker chamber, specimen holder and microphone ports.

The sound absorption coefficient α (0…1) describes the ratio of absorbed to incident sound energy.

Reverberation-room values are generally requested in building construction; impedance-tube values are used for industrial noise control, building services and vehicle acoustics.

Reverberation time EN ISO 3382

Measurement room and waterfall plot of the measured impulse response over frequency and time.

The reverberation time RT60 is the time a room takes after excitation (for example by an impulse) for the level to decay by 60 dB. In a reverberant room such as a church, reverberation time can readily exceed 5 s, whereas in a dry room such as a recording-studio control room it may be only 0.4 s or less. RT60 can be determined in several ways.

  1. The room is excited with an impulse, and the complete sequence including the decay is recorded with a sound level meter. Reverberation time can be determined from the level decay rate [dB/s]. Filtering into individual frequency bands usefully shows its frequency dependence.

  2. Method 1 also works very well by switching off a noise source.

  3. The level decay rate can be calculated from the room impulse response by backward integration of the squared impulse response. This method, which we also use, offers flexibility in filtering and calculating other room acoustic parameters.

Multiple measurements from different source and measurement positions must always be averaged.

Room impulse response

Measured room impulse response shown in full and as an enlarged detail of the direct sound.

The impulse response is the sound-pressure time signal produced when a room is excited by an ideal impulse — and it always relates to the specific measurement path from source to receiver. It can be used to calculate many other room-acoustic parameters that cannot be obtained from a reverberation-time measurement.

Measurement method: play a defined signal sequence over a loudspeaker, record and digitise the complete sequence, then calculate the impulse response by deconvolution.