Expert reports & compliance assessments

Do you need an expert assessment, a report or evidence of compliance? We act as commercially independent experts, using METAS-calibrated instruments and standards-compliant measurement methods.

Site plan of a housing development with the assessed noise levels calculated at individual points.

Verification measurements

Excerpt from an anonymised SIA 181 measurement report with test setup, results table and assessment.

We perform standards-compliant verification measurements for:

All measurements use METAS-calibrated instruments. Our reports clearly document the methods and results.

For formal measurements under LSV, we use approved Class 1 sound-measuring instruments with current legal verification. The instruments are reverified within the prescribed periods and calibrated with a legally verified calibrator before every use. The report clearly documents the measurement setup, operating conditions, raw data and analysis so that the assessment can be checked.

Residential noise: legal framework and formal evidence

Measurement microphone at an open bedroom window, with technical equipment outdoors.

Rented accommodation. The landlord must maintain the property in a condition fit for its intended use. A material acoustic defect may therefore give rise to claims under Articles 256 and 259a et seq. of the Swiss Code of Obligations (OR). Whether a defect exists and what claim is justified depends on the building, contract and noise; a measurement report provides an important basis for the next steps but does not in itself determine the legal claim.

Construction or building-services defect. SIA 181 is relevant to sound insulation between occupancy units and noise from building-services equipment. The applicable limit for a room depends on factors such as the type of noise, use, noise sensitivity and requirement level.

Fixed installations outside the building. Heat pumps and many industrial and commercial installations are assessed under the Swiss Environmental Protection Act (USG) and Swiss Noise Abatement Ordinance (LSV). Planning values generally apply to new installations; for existing installations, the immission limit is central to the need for remediation. Two sensitivity levels (ES) commonly encountered in residential situations under Annex 6 LSV, with planning value (PW) and immission limit value (IGW):

These are rating levels Lr and cannot be compared directly with a measured value. Operating duration, tonal and impulsive content, time of day, sensitivity level and the installation's legal status enter the assessment through correction factors. For buildings, outdoor noise is generally determined at the centre of the open window of a noise-sensitive room.

Other neighbourhood and everyday noise. Where LSV specifies no fixed exposure limit, the enforcement authority or court assesses the individual case. Article 684 of the Swiss Civil Code (ZGB) may also apply to excessive effects between properties. Loudness alone is then not decisive; character, frequency, duration, time of day and local conditions also count.

A formal determination under LSV may be based on a calculation or measurement. The technical requirements for formal measurement and its documentation are given in the Verification measurements section. LSV does not prescribe a specific professional title for the person carrying out the work. However, because extraneous sound sources must be distinguished, level corrections applied and the legal context established, cantonal enforcement guidance for noise reports calls for professional experts with in-depth acoustics expertise. The enforcement authority assesses the result or orders further investigation.

Workplace noise (SUVA / ArGV 3)

Person measuring noise beside a production machine; a measurement microphone is mounted on a tripod.

We measure workplace noise levels and assess the situation in accordance with SUVA guidelines and Swiss labour law:

Expert assessments and second opinions

Construction plan with handwritten notes on a table, beside a measurement log, pen and sound level meter.

We act as independent consultants and experts in the following fields:

By "independent" we mean genuine commercial independence. We work across all sectors of the economy — our client base is exceptionally diverse.